FEMA菲玛压力开关/压力变送器Type series DNM系列选型资料 | ||||||||||||||||||||||||||||||||
Technical data Pressure connection External thread G 1/2 (pressure gauge connection) according to DIN 16 288 and internal thread G 1/4 according to
ISO 228 Part 1.Switching device Robust housing (700) made of seawater resistant die cast aluminium GD Al Si 12.Protection class IP 65, in vertical position.Pressure sensor materials Ex-DNM Metal bellows: 1.4571 Sensor housing: 1.4104 Ex-DCM4016/ Diaphragm: Perbunan Ex-DCM4025 Sensor The most important types of ignition protection for FEMA products are as follows:"Ex-d" pressure proof encapsulation EN 60079-1"Ex-e" enhanced safety EN 60079-7"Ex-t" protection via housing EN 60079-31 "Ex-i" intrinsically safety EN 60079-11 Pressure switches Specially
designed FEMA Ex-protected pressure switches are available for use in ex-protection areas. They conform to these standards and are type-tested
(Ex-d, Ex-e, Ex-t) and / or have been technically prepared for these areas (Ex-i)."Ex-d" Pressure-Proof Encapsulation Switch components and other
electrical functional units capable of igniting explosive gas mixtures are encapsulated in a housing which will survive the explosive pressure of an internal
explosion and the special design of which prevents the transference of this explosion to the ambient atmosphere. Ex-DCM4016 1…16 mbar 0,2 ... 2 mbar 1 bar Perbunan 4 + 11 Ex-DNM10 1…10 bar 0,05 ... 0,3 bar 25 bar 4 + 17 DPS200 20...200 (Pa) 10 (Pa) ±5% (min. 5 Pa) |
|||||||||||||||||||||||||||||||||
1. Type of ignition protection Ex-d, Ex-e and Ex-t:The pressure switch with protection type "Flameproof Ex-d and Increased Safety Ex-e" can be used with the switch device in hazardous areas of zone 1 and 2 for flammable gas mixtures. For use in dust atmospheres, the protection is "protected by enclosure Ex-t". The switching device may be used in hazardous areas of zones 21 and 22 for explosive dusts. In addition, for the dust explosion protection zone 20 on the sensor (device screwed into container walls, which may occur in the interior permanent dust atmosphere). The permissible values for switching voltage, switching capacity and ambient temperature please refer to the detailed description of the Ex-equipment, and the installation and operating instructions. In addition, please note the general rules for the use and installation of equipment in hazardous atmosphere.Special circuits, as well as versions with adjustable switching differential or internal interlock (reclosing lock) are not possible.2. Ignition protection Ex-i All pressure switches with features for intrinsically safe circuits can be used with the switching device in hazardous areas Zone 1 and 2 (Gas) and zones 21 and 22 (Dust). In addition, the sensor in hazardous areas Zone 0 (Gas) and 20 (Dust) may be screwed. (Inside tank = defined as zone 0 or zone 20). A circuit is considered to be "intrinsically safe" if the amount of energy conveyed therein is not capable of generating an ignitable sparks. This pressure switch can only be operated in combination with a suitable isolating switching amplifier, which is approved for the type Ex-i. Suitable variants must be selected for this pressure switch with resistor combination for line and short circuit monitoring. Because of the low voltages and currents in intrinsically safe circuits, micro switches with gold contacts are used for pressure monitors with automatic reset. For limiter (with internal interlock) micro switches with silver contacts are used. FEMA pressure switches for use in intrinsically safe circuits are marked by blue terminals and cable entries. In addition, the pressure switch has been tested by a "notified body". The units get a serial number and the nameplate inform about the ignition protection and registration number.Ignition protection for pressure monitoring in Zones 0 (20), 1 (21) and 2 (22) Trennschalterverstärker Pressure proof encapsulation Ex-d (EN 60079-0:2009) Enhanced safety Ex-e (EN 60079-7:2007) Protection via housing Ex-t (EN60079-31:2009) | |||||||||||||||||||||||||||||||||
上海泽鹏科技发展有限公司 | 电话 : 021-3778503 手机 : 17821719638 | 邮箱 : E-mail:zepengtech@163.com | 上海市新龙路311弄宝龙城T6栋507室 | |||
友情链接: 仙童FAIRCHILD | 柏勒夫Bellofram | ADI亚德诺芯片 | 新闻报道:中国北斗导航系统《纽约时报》报道 | ML5720A0500/执行器/驱动器 |
神钢SHINKO | 三菱MITSUBISHI | 6000-EA放大器 | 仙童 | 淘宝网 | 霍尼韦尔Honeywellfema参加上海工业展进口博览会 | ML5720A1000/执行器/驱动器 |
欧姆龙OMRON | 日精NISSEI GTR | 压力开关DCM1 | 压力开关EX-DWR 3 | 神钢电机SHINKO市场分析研讨会 | ML5740A2000/执行器/驱动器 |
亚司艾自控 | SOR索尔 | 诺冠Norgren | 压力开关DCM10 | 压力开关EX-DWR25 | 西门子楼宇和工业仪表 | 阿里巴巴 | ML5740A2500/执行器/驱动器 |
版权所有@上海泽鹏科技发展有限公司 | 沪ICP备18041004号-3 | ML5740A3000/执行器/驱动器 |