==专业销售_FEMA压力开关_压力变送器_费玛压力开关_费玛压力变送器_菲玛压力开关_菲玛压力变送器 |
FEMA菲玛销售热线/微信: 17821719638 |
公司首页 | | | 新闻动态 | | | 公司简介 | | | 产品展示 | | | 案例应用 | | | 产品资料 | | | 技术参数 | | | 人才招聘 | | | 联系我们 |
---|
FEMA菲玛压力开关/压力变送器Type series DNM系列选型资料 | ||||||||||||||||
|
||||||||||||||||
EX-DCM4025压力开关,FEMA代理,菲玛代理,EX-DCM4016,EX-DCM4025,EX-DNM10,EX-DNM63,DCM25,DWR3,DPS200,DPS400,DPS500,DPS1000,DPS2500 Technical data Pressure connection External thread G 1/2 (pressure gauge connection) according to DIN 16 288 and internal thread G 1/4 according to
ISO 228 Part 1.Switching device Robust housing (700) made of seawater resistant die cast aluminium GD Al Si 12.Protection class IP 65, in vertical position.Pressure sensor materials Ex-DNM Metal bellows: 1.4571 Sensor housing: 1.4104 Ex-DCM4016/ Diaphragm: Perbunan Ex-DCM4025 Sensor Ex-DCM4016 1…16 mbar 0,2 ... 2 mbar 1 bar Perbunan 4 + 11 Ex-DNM10 1…10 bar 0,05 ... 0,3 bar 25 bar 4 + 17 DPS200 20...200 (Pa) 10 (Pa) ±5% (min. 5 Pa) |
||||||||||||||||
G e n e r a l i n f o r m a t i o n a b o u t explosion p r o t e c t i o n Zone classification Explosion risk areas are grouped into zones according to the likelihood of a dangerous explosive atmosphere according to EN 1127-1 occurring. When assessing the explosion hazard, i.e. when identifying explosion risk areas, the "Guidelines for the Avoidance of Danger due to Explosive Atmospheres with Examples (ExRL)" of the German Insurance Association for the Chemical Industry must be taken into account. If the situation concerns a special case or if doubts exist as to the definition of explosion risk areas, the matter shall be decided by the supervisory authorities (Trade Supervisory Office, where applicable with the assistance of the Insurance Association or the Technical Control Boards. In Zones 0 (20) and 1 (21), only electrical equipment for which a type test certificate has been issued by a recognized testing agency may be used. In Zone 0 (20), however, only equipment expressly authorized for that zone may be used. Equipment approved for use in Zones 0 (20) and 1 (21) may also be used in Zone 2 (22). Under the new European Directive 94/9 EC (ATEX 100a), a distinction is made between gas atmospheres and dust atmospheres. This results in the following zone |
||||||||||||||||
上海泽鹏科技发展有限公司 | 电话 : 021-3778503 手机 : 17821719638 | 邮箱 : E-mail:zepengtech@163.com | 上海市新龙路311弄宝龙城T6栋507室 | |||
友情链接: 仙童FAIRCHILD | 柏勒夫Bellofram | ADI亚德诺芯片 | 新闻报道:中国北斗导航系统《纽约时报》报道 | 电气转换器550-AF |
神钢SHINKO | 三菱MITSUBISHI | 6500-EA放大器 | 仙童 | 淘宝网 | 霍尼韦尔Honeywellfema参加上海工业展进口博览会 | 电气转换器550-BC |
欧姆龙OMRON | 日精NISSEI GTR | 压力开关DCM1 | 压力开关EX-DWR16 | 神钢电机SHINKO市场分析研讨会 | 电气转换器550-BD |
亚司艾自控 | SOR索尔 | 诺冠Norgren | 压力开关DCM16 | 压力开关EX-DWR25 | 西门子楼宇和工业仪表 | 阿里巴巴 | 电气转换器550-BE |
版权所有@上海泽鹏科技发展有限公司 | 沪ICP备18041004号-3 |